Tekla Tedds Engineering Library (December 2018)

Tekla Tedds
2018
Tekla Tedds Tekla Tedds for Word
Environment
British Standard
Eurocode
USA
Materials
Concrete
Masonry
Steel

Contents

UK and Asia

Column base plate design (EN1993)
Masonry column design (EN1996)
RC wall design (EN1992)

Enhanced output options including a summary table showing the key results which allows anyone reviewing the output to quickly determine the overall status of the design. A user defined note can also be included in the output to add information which is relevant to the specific design case.

Other updates

Column base plate design (EN1993)

[TEDDS-2963]1 Fixed "specified result units do not match dimensions of expression" error when selecting C50/60.

Masonry column design (EN1996)

Fixed output results not displaying the critical case.

RC wall design (EN1992)

[TEDDS-2011]1 Changed vertical reinforcement in outer layer option to be disabled by default.

USA

Flagpole embedment (IBC)
Pile analysis (FHWA)

Enhanced in accordance with IBC 2018.

Other updates

Pile analysis (FHWA)

[TEDDS-949]1 Fixed script error where lateral analysis graphs are invalid.
[TEDDS-918]1 Revised soil type warning check to compare only to soils within the critical depth.
[TEDDS-882]1 Fixed H pile perimeter calculation for plugging action condition, no effect on calculated results.

Wind loading (ASCE7)

[TEDDS-2518]1 - Fixed a drop list in the user interface to display only the applicable wall zones for components and cladding load cases.
Fixed an intermittent undefined variable error when amending roof zones for components and cladding load cases.

Australia

No Updates

Canada

No Updates

Europe

Column base plate design (EN1993)
Masonry column design (EN1996)
RC wall design (EN1992)

Enhanced output options including a summary table showing the key results which allows anyone reviewing the output to quickly determine the overall status of the design. A user defined note can also be included in the output to add information which is relevant to the specific design case.

Other updates

Column base plate design (EN1993)

[TEDDS-2963]1 Fixed "specified result units do not match dimensions of expression" error when selecting C50/60.

Masonry column design (EN1996)

Fixed output results not displaying the critical case.

RC wall design (EN1992)

[TEDDS-2011]1 Changed vertical reinforcement in outer layer option to be disabled by default.

Footnotes

1 This number is an internal reference number and can be quoted to your local Support Department should further information on an item be required.