Tekla Tedds Engineering Library (July 2021)

Last updated July 15, 2021 by Tedds Development Team tekla-product-development-tedds-team-ug@trimble.com

Tekla Tedds Engineering Library (July 2021)


UK and Asia

Windpost design (EN1993)

New calculation which checks the design of a vertical steel beam acting as a windpost providing lateral support to a masonry wall subjected to a uniformly distributed wind load. Checks the capacity of the wall ties to distribute the wind loads from the loaded leaf to the other leaf. In accordance with EN1993 & EN1996 and the national annex for the UK, Ireland, Singapore, Malaysia, Finland, Sweden, Norway or the recommended Eurocode values.

Video demonstration

Other updates

RC corbel design (EN1992)

[TEDDS-5803]1 - Enhanced to include C32/40 concrete grade
[TEDDS-5804]1 - Enhanced to removed limits on the number of legs per link

[TEDDS-5786]1 - Typos in the reinforcement dialog corrected.

RC pile cap design (EN1992/EN1997)

[TEDDS-5737]1 - Fixed preview results error re column punching shear check.
[TEDDS-5726]1 - Fixed pile arrangement validation in the interface not taking into account the pile location tolerance and the pile equivalent length.

Rolling load analysis

[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.

Timber connection design (EN1995)

[TEDDS-5445]1 - Correct spurious spacing check fail message associated with a single row of fixings.
[TEDDS-5798]1 - Correct expression error if output options dialog isn't accessed before finishing the UI.

USA

Updates

Rolling load analysis

[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.

Europe

New calculation which checks the design of a vertical steel beam acting as a windpost providing lateral support to a masonry wall subjected to a uniformly distributed wind load. Checks the capacity of the wall ties to distribute the wind loads from the loaded leaf to the other leaf. In accordance with EN1993 & EN1996 and the national annex for the UK, Ireland, Singapore, Malaysia, Finland, Sweden, Norway or the recommended Eurocode values.

Video demonstration

Other updates

RC corbel design (EN1992)

[TEDDS-5803]1 - Enhanced to include C32/40 concrete grade
[TEDDS-5804]1 - Enhanced to removed limits on the number of legs per link

[TEDDS-5786]1 - Typos in the reinforcement dialog corrected.

RC pile cap design (EN1992/EN1997)

[TEDDS-5737]1 - Fixed preview results error re column punching shear check.
[TEDDS-5726]1 - Fixed pile arrangement validation in the interface not taking into account the pile location tolerance and the pile equivalent length.

Rolling load analysis

[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.

Timber connection design (EN1995)

[TEDDS-5445]1 - Correct spurious spacing check fail message associated with a single row of fixings.
[TEDDS-5798]1 - Correct expression error if output options dialog isn't accessed before finishing the UI.

Australia

Updates

Rolling load analysis

[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.

Canada

Updates

Rolling load analysis

[TEDDS-5767]1 - Fixed Area of section reverting to the default value when defining a custom section due to previous fix [TEDDS-3965]1.

Footnotes

1 This number is an internal reference number and can be quoted to your local Support Department should further information on an item be required.

Content rating: 
No votes yet