I cannot activate my Tekla Tedds PAK - The message "The product activation key you have entered is not a local computer locked license product activation key" is displayed. How can I resolve this?

Question I have installed Tekla Tedds but when I try to activate my Product Activation Key (PAK) the message "The product activation key you have entered is not a local computer locked license product activation key" is displayed.  Answer If the PAK code you have received begins with "42334" or "52334" then this is a Server (network) license. This means that the license can be activated (and used) on one machine (this machine will become the 'license server'), and any other machine connected to your network can also use the license (see further below for information on how to do this). Follow
by Trimble Solutions UK
0
  • Product Activation Key
  • PAK
  • Error
  • Activate
  • The product activation key you have entered is not a local computer locked license product activation key

I cannot launch Tedds. "Error 25" is displayed within the License Manager. How can I resolve this?

Question When attempting to launch Tedds the License Manager launches instead, stating Error 25 within the Status page. Answer Upgrade the Tekla License Service on the License Server. This can be downloaded from our website here and must be installed onto the License Server with the following options (include the third option if Tedds is also used on the license server):   Due to significant changes to the current version of the Tekla License Service, this upgrade is required on the license server to enable the use of Tedds 2017 (or any product downloaded after March 2017). This installation
Requires Tekla Maintenance
by Trimble Solutions UK
0
  • Error 25
  • Error
  • License Manager
  • Server

I cannot launch Tedds. "Error 18" is displayed within the License Manager. How can I resolve this?

Question: When attempting to launch Tedds, the License Manager is launched instead, displaying "Error 18" within the Status page. Answer: Check whether a license has been issued for the version of Tedds that you have installed - if not, you can request this from your local Trimble office If you have been issued a license for the version you have installed, ensure that this has been activated on your server If your license has been activated on your server, ensure that you have configured your licensing settings to use the correct server as shown below Go to Start > All Apps > Tekla
Requires Tekla Maintenance
by Trimble Solutions UK
0
  • Error 18
  • Error
  • License Manager
  • License

I cannot launch Tedds when connecting over a VPN. What changes can I make to resolve this?

Question When I try to launch Tedds when connecting across a VPN, the License Manager launches instead, displaying errors. This issue does not occur when connecting over my local network. What changes can I make to resolve this? Answer When I attempt to use Tedds across a VPN, connection issues between the server and client machines may occur, preventing Tedds from launching.  A common cause of this can be the firewall on the server and/or the client machine(s) blocking the License Service and possibly Tedds/Structural Designer due to IP packet encryption across the VPN. Exclusions To start
Requires Tekla Maintenance
by Trimble Solutions UK
0
  • VPN
  • Error
  • License Manager

Since installing Tekla Tedds 2017 Windows seems to sometimes restart unexpectedly - are they connected?

We have had isolated reports, that under some specific circumstances, that after installing Tekla Tedds 2017 some Windows 7 machines are experiencing an intermittent issue whereby the machine reboots shortly after the first boot of the day. Diagnosis Unfortunately the reboot is a failure of Windows at the lowest level and therefore there is no information logged in the Event log or captured by a MiniDump. We have managed to track down the issue to be related to a Compatibility update for Windows 7 deployed by a Microsoft Update. The update creates a scheduled task which performs diagnostics
by Tekla User Assistance Team
5
  • windows 7
  • restart
  • reboot

Tedds Engineering Library (May 2017)

Contents UK and Asia USA Australia Canada Europe Common UK and Asia Product bulletin May 2017 (PBT-1705-1) Masonry bearing design (EN1996) - There is a potentially un-conservative error affecting designs if the eccentricity of the concentrated load is out of the plane of the wall panel. For more detailed information please refer to "Product bulletin May 2017 (PBT-1705-1)" in the Bulletins group of the Engineering Library Index. Other updates RC column design (BS8110) Corrected application of additional moments due to slenderness for unbraced columns with uniaxial bending. RC corbel design (
by Tedds Development Team
0

Tekla Tedds product bulletin May 2017 (PBT-1705-3)

Résumé of issue Timber beam analysis & design (AS1720) There is a potentially un-conservative error affecting members designed using laminated veneer lumber (LVL). Occurrence This issue relates to Tedds 2017 from April 2017, Tedds 2016 from March 2016, Tedds 2015 from June 2015, Tedds 2014 from June 2014, Tedds 2013 from May 2013 and Tedds 14 from October 2011: Timber beam analysis & design (AS1720) version 1.5.02 – 1.7.00
Requires Tekla Maintenance
by Tedds Development Team
0

Tekla Tedds product bulletin May 2017 (PBT-1705-2)

Résumé of issue Masonry wall panel design (MSJC) There is a potentially un-conservative error affecting the design of walls subject to out of plane loads designed using the Strength design method. Occurrence This issue relates to Tedds 2017 from April 2017: Masonry wall panel design (MSJC) versions 2.2.00
Requires Tekla Maintenance
by Tedds Development Team
0

Tekla Tedds product bulletin May 2017 (PBT-1705-1)

Résumé of issue Masonry bearing design (EN1996) There is a potentially un-conservative error if the eccentricity of the concentrated load is out of the plane of the wall panel. Occurrence This issue relates to Tedds 2017 from March 2017, Tedds 2016 from March 2016, Tedds 2015 from June 2015, Tedds 2014 from June 2014: Masonry bearing design (EN1996) versions 1.0.00 – 1.0.06
Requires Tekla Maintenance
by Tedds Development Team
0

Why is my antivirus flagging the Tekla install file as containing a threat?

We have seen a few reports from users whereby some antivirus software flags the Tekla installation files as containing a threat, for example: We have processes in place to ensure our downloads do not contain threats, but sometimes antivirus programs will flag them with what is called a false positive. In order to verify that the file you have downloaded is the same file that we have distributed please check the hash of the file you have downloaded before running the downloaded file on your system. Tekla Tedds Filename: setup_tekla_tedds_2017_mar2017.exe SHA256:
Requires Tekla Maintenance
by Tekla User Assistance Team
0
  • antivirus
  • AVG
  • Symantec

Tedds Engineering Library (April 2017)

Contents UK and Asia USA Australia Canada Europe Common UK and Asia 2D analysis Enhanced output including: Force and deflection results tables highlight overall max and min results. Member, span and element loads are each presented in a single table for all load types. Loading section now indicates whether self-weight is included and excludes the self-weight load case drawing. Increased precision of output results for US units to 3 decimal places to allow for light loading conditions. When the model is of a single design member or if intermediate results are enabled, the force results
by Tedds Development Team
0

Why does my unreinforced masonry retaining wall design use a characteristic flexural strength of zero?

Question Why does my unreinforced masonry retaining wall design use a characteristic flexural strength of zero?    Answer When using the retaining wall analysis and design (EN1992/EN1997/EN1997) calculation for an unreinforced masonry wall panel calculation to EC 1992, the flexural strength of the wall is always zero (0) therefore relying on the axial load on the wall for bending resistance. The source information for the flexural strength (fxk) being zero is BS EN 1996-1-1:2005 Note 1 of clause 6.3.4 in the code which states: The flexural strength of masonry fxk1 [i.e. that parallel to the
Requires Tekla Maintenance
by Trimble Solutions UK
5
  • unreinforced masonry
  • flexural strength
  • zero
  • retaining wall

How do I resolve problems when installing or launching Tedds 2017?

The majority of installation and setup issues can be resolved by simply making sure your computers operating system and software are up to date. If we are unable to replicate a problem the issue will almost certainly be related to your specific computer setup. General Please ensure that: Your system meets at least the minimum system requirements You have all the latest Windows updates installed. You can check by running ‘Windows Update’ Your anti-virus software is up to date You have the latest version of Tekla Tedds installed: Tedds 2017 You have all the latest Tekla Tedds updates installed
Requires Tekla Maintenance
by Tekla User Assistance Team
0

Tekla Tedds product bulletin April 2017 (PBT-1704-1)

Résumé of issue Masonry wall panel design (MSJC) There is a potentially un-conservative error affecting the design of walls designed using strength design standards. Occurrence This issue relates to Tedds 2017 from March 2017, Tedds 2016 from March 2016, Tedds 2015 from June 2015, Tedds 2014 from September 2014 and Tedds 2013 from September 2013: Masonry wall panel design (MSJC) version 2.0.07 – 2.1.06
Requires Tekla Maintenance
by Tedds Development Team
0

Tekla Tedds product bulletin March 2017 (PBT-1703-2)

Résumé of issue Masonry bearing design (EN1996) There is a potentially un-conservative error affecting designs where the normalised mean compressive strength value is modified from its initial value. Occurrence This issue relates to Tedds 2017 from March 2017, Tedds 2016 from September 2016: Masonry bearing design (EN1996) versions 1.0.04 – 1.0.05
Requires Tekla Maintenance
by Tedds Development Team
0

How do I join a Tekla Online Service Organization?

There are a couple of ways to become part of your Tekla Online Service Organization Via your Profile Open your profile page The service will attempt to suggest an Organization based on your email address  If it finds one then click the Request Invite You will also need to let your Tekla Online Service Organization adminstrator know you have requested an invite Via your Tekla Online Service Organization adminstrator You would need to contact your Tekla Online Service Organization adminstrator and request they send you an invite into your Tekla Online Service Organization. Your Tekla Online
Requires Tekla Maintenance
by Tekla User Assistance Team
0
  • Tekla Online Service

Tekla Tedds product bulletin March 2017 (PBT-1703-1)

Résumé of issue Masonry wall panel design (MSJC) There is a potentially un-conservative error affecting the design of special reinforced shear walls designed to allowable stress design standards. Occurrence This issue relates to Tedds 2017 from March 2017, Tedds 2016 from March 2016, Tedds 2015 from June 2015 and Tedds 2014 from September 2014: Masonry wall panel design (MSJC) version 2.1.02 – 2.1.06
Requires Tekla Maintenance
by Tedds Development Team
0

Is Tekla Structural License Service compatible with Microsoft Server 2016?

Update: Although we don't yet test the Tekla Structural License Service on Windows Server 2016, Tekla Structural License Service v2.04, first released in February 2018, includes Sentinel RMS 9.2 which officially supports Windows Server 2016. The 3rd party licensing service, Sentinel RMS License Service, packaged with Tekla Structural License Service v2.02, shipped in March 2017, is only officially supported by it's developers Gemalto (previously SafeNet) on Windows Server 2008, 2008 R2, 2012 and 2012 R2. So currently Windows Server 2016 is not yet officially supported. However in practice 
Requires Tekla Maintenance
by Tekla User Assistance Team
5
  • License Service
  • license server
  • compatibility
  • Microsoft Server 2016

Tekla Tedds 2017 release notes

What’s New? Some features documented below were included in previous updates to Tekla Tedds 2016. Engineering library (United Kingdom & Asia) 2D steel member analysis & design (EN1993) Steel member analysis & design (EN1993) Enhanced to allow non horizontal members to be designed. Steel column and base plate design (EN1993) New calculation which integrates the Steel column design and Column base plate design calculations to provide a single design for both a column and a connected base plate. RC corbel design (EN1992) New calculation for the design of reinforced
by Tekla User Assistance Team
5

Tekla Tedds 2017 system requirements

Minimum spec CPU: P4 (3.0GHz) Memory: 1GB Disk space: 300MB OS: Windows 7 (SP1) Graphics: 1024x768 Recommended spec CPU: Intel Core i3 2.0GHz (or equivalent) Memory: 2GB Disk space: 500MB OS: Windows 7/8.1/10 64-bit Graphics: 1024x768 Supported operating systems Tedds 2017 is tested and supported on the following business versions of Microsoft Windows: Windows 10 32-bit and 64-bit Windows 8.1 32-bit and 64-bit Windows 7 (SP1) 32-bit and 64-bit Additional requirements Tedds for Word requires a fully service packed version of Microsoft Word 2010, 2013 or 2016, 32-bit or 64-bit. Operating